Go Back Research Article August, 1998

PRESSURE DROP IN FIXED, EXPANDED AND FLUIDIZED BEDS, PACKED COLUMNS AND STATIC MIXERS - A UNIFIED APPROACH

Abstract

On the basis of force and energy balance, a generalized approach has been developed for the prediction of pressure drop in fixed, expanded and fluidized beds, packed columns and static mixers. It has been shown that the Ergun type equation can be derived from first principles. i) Pressure drop in fixed, fluidized and expanded beds: Spherical particles

Keywords

Pressure Drop Fixed Beds Expanded Beds Fluidized Beds Packed Columns Static Mixers Unified Approach Force Balance Energy Balance Generalized Prediction Ergun Equation First Principles Spherical Particles Hydrodynamics Flow Resistance Particle Packing Bed Expansion Fluid Flow Pressure Drop Correlation Chemical Engineering Reactor Design
Details
Volume 14
Issue 4-5
Pages 321-371
ISSN 2191-0235